Before Picture
Before
After Picture
After

Cleaning Trial Summary

 

The customer was looking to improve their cleaning performance and automat their cleaning process.

Cleaning Trial Type
Temperature
Aqueous
160⁰F
Industry
Time Required
Remanufacturing
3.5 – 8 hours
Segment
Substrate
Fabricated Metal Product
Steel
Soil
Baked on Carbon
Description of Part(s)
Steel cuffs
Cleaner Used
Machine Used
  1. Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000)
  2. Ultrasonic Washer (SK 6315)
  3. Spray Under Immersion Washer (Graymills T12, Graymills T24, SK 81.8 w/SUI)
Post Cleaning

Fresh water rinse followed by air pressure drying.

Recommendation to Customer

The ArmaKleen Technical Center recommended using 10% by volume ArmaKleen™ M-301 at 160⁰F in an Ultrasonic Washer for a minimum of 3.5 hours.