Before Picture
Before
After Picture
After

Cleaning Trial Summary

 

The customer was looking to automate their cleaning process, reduce rework and reject rate, eliminate hazardous chemicals and waste and reduce VOCs.

Cleaning Trial Type
Temperature
Ink
160⁰F
Industry
Time Required
Printing
30 minutes to 4 hours
Segment
Substrate
Machine Manufacturing
Steel
Soil
Ink, Toner Residue
Description of Part(s)
Steel augers
Cleaner Used
Machine Used

Ultrasonic Washer (SK 6315 Blackstone Model 3523)

Post Cleaning

Fresh water rinse followed by air pressure drying

Recommendation to Customer

The ArmaKleen Technical Center recommended using 100% by volume ArmaKleen™ Paint and Ink Remover at 160⁰F in an Ultrasonic Washer for a minimum of 30 minutes to 4 hours.