Before Picture
Before
After Picture
After

Cleaning Trial Summary

Auto Maintenance :: TSR #15-A-171

 

The customer was looking to improve their cleaning performance, automate their cleaning process and reduce rework and reject rate.

Cleaning Trial Type
Temperature
Aqueous
160°F
Industry
Time Required
OEM parts manufacturing
15 to 30 minutes
Segment
Substrate
Auto Maintenance
Steel
Soil
Cutting Fluids, Oil
Description of Part(s)
Drill Bits
Cleaner Used
Machine Used

1.       Spray Washer (JRI FL250, JRI FL500, JRI TL3, Better Engineering G-2000)

2.       Ultrasonic Washer (Blackstone SK6315)

Post Cleaning

Fresh water rinse followed by air pressure drying.

Recommendation to Customer

 The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 160°F in either a Spray Washer or an Ultrasonic Washer for a minimum of 15 to 30 minutes.