Cleaning Trial Summary

Auto Maintenance :: TSR #15-A-208

 

The customer was looking to improve their cleaning performance and reduce rework and reject rate.

Cleaning Trial Type
Temperature
Aqueous
160°F
Industry
Time Required
Transmission Remanufacturing
15 to 30 minutes
Segment
Substrate
Auto Maintenance
Brass, Plastic, Rubber, Stainless Steel, Steel
Soil
Oil
Description of Part(s)
Plug
Cleaner Used
Machine Used

Ultrasonic Washer (Blackstone SK 6315)

Post Cleaning

Fresh water rinse followed by air pressure drying.

Recommendation to Customer

The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 15 to 30 minutes.