Before Picture
Before
After Picture
After

Cleaning Trial Summary

Auto Dealership :: TSR #15-A-219

 

The customer was looking to improve their cleaning performance, automate their cleaning process and eliminate hazardous chemicals and waste.

Cleaning Trial Type
Temperature
Aqueous
160°F
Industry
Time Required
Turbocharger repair/ remanufacturing
2 hours
Segment
Substrate
Auto Dealership
Stainless Steel
Soil
Baked on Carbon, Fuel deposits
Description of Part(s)
Turbine blades
Cleaner Used
Machine Used

Ultrasonic Washer (Blackstone SK 6315)

Post Cleaning

 Fresh water rinse followed by air pressure drying.

Recommendation to Customer

The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 2 hours or using 10% by volume ArmaKleen™ M-301 at 160°F in an Ultrasonic Washer for a minimum of 2 hours.