Before Picture
Before
After Picture
After

Cleaning Trial Summary

 

The customer was looking to improve their cleaning process, reduce rework and reject rate and eliminate hazardous chemicals and waste.

Cleaning Trial Type
Temperature
Aqueous
160°F
Industry
Time Required
Manufacturing
8 hours
Segment
Substrate
Fabricated Metal Product
Rubber, Stainless Steel, Steel
Soil
Adhesive, Glue, Oil
Description of Part(s)
Nozzles and connectors
Cleaner Used
Machine Used

Ultrasonic Washer (Blackstone SK6315)

Post Cleaning

Fresh water rinse followed by air pressure drying.  Several threaded areas where lightly brushed with a stainless steel bristle brush during the fresh water rinse.

Recommendation to Customer

 The ArmaKleen Technical Center recommended using either 5% by volume ArmaKleen™ 4 in 1 Cleaner or 10% by volume ArmaKleen™ M-301 at 160°F in an Ultrasonic Washer for a minimum of 2 to 8+ hours.