Before
After

Cleaning Trial Summary

 

The customer was looking to improve their cleaning performance, automate their cleaning process, reduce rework and reject rate, reduce their cleaning costs and eliminate hazardous chemical/waste.

Cleaning Trial Type
Temperature
Aqueous
140°F
Industry
Time Required
Fastener Distribution
15-30 minutes
Segment
Substrate
Miscellaneous Manufacturing
Brass
Soil
Diesel Oil, Grease, Grime, Oil, Rust/Oxides, Shop Dirt
Description of Part(s)
Thirteen 360-brass connectors
Cleaner Used
Machine Used

Ultrasonic Washer (SK Blackstone 6315)

Post Cleaning

Fresh water rinse followed by air pressure drying 

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 15-30 minutes.