Before
After

Cleaning Trial Summary

 

The customer was looking to improve their cleaning performance, automate their cleaning process, reduce their cleaning costs and reduce VOCs.

Cleaning Trial Type
Temperature
Aqueous
150 - 160°F
Industry
Time Required
Metal Manufacturer
15-30 minutes
Segment
Substrate
Miscellaneous Manufacturing
Stainless Steel
Soil
Reno Form, Twin Draw
Description of Part(s)
Six 22.75”l x 5.75”d stainless steel tubes
Cleaner Used
Machine Used

·         Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000

·         Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/SUI)

Post Cleaning

Fresh water rinse followed by air pressure drying.

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in a Spray Washer for a minimum of 15-30 minutes.