Before
After

Cleaning Trial Summary

Auto Maintenance :: TSR #16-P-042

 

The customer was looking to improve their cleaning performance.

Cleaning Trial Type
Temperature
Paint
160°F
Industry
Time Required
Automotive parts manufacturer
4 hours
Segment
Substrate
Auto Maintenance
Steel
Soil
Gasket Material
Description of Part(s)
a steel transmission valve-body plate
Cleaner Used
Machine Used

Ultrasonic Washer (SK Blackstone 6315)

Post Cleaning

Fresh water rinse followed by air pressure drying

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 100% by volume solution of ArmaKleen™ Paint and Ink Remover at 160°F in an Ultrasonic Washer for a minimum of 4+ hours.