Before
After

Cleaning Trial Summary

 

The customer was looking to improve their cleaning performance.

Cleaning Trial Type
Temperature
Aqueous
160°F
Industry
Time Required
Plant sterol production
1 hour
Segment
Substrate
Miscellaneous Manufacturing
Steel
Soil
Baked on tall oil
Description of Part(s)
Five steel bolts with steel washers
Cleaner Used
Machine Used

Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000)

Post Cleaning

Fresh water rinse and air pressure dried. Several areas of the threaded bolt were lightly brushed with a stainless steel bristle brush during the fresh water rinse.

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ M-100 BCR at 160°F in a Spray Washer or a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in a Spray Washer for a minimum of 1 hour.