Cleaning Trial Summary
Customer Objective
              Improve cleaning performance, automate cleaning process, reduce rework and reject rate, clean mixed metals together, reduce cleaning costs
            Cleaning Trial Type
          
          
            Temperature
          
        
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     Aqueous
                     
                     
          
          
          Temperature
              160°F
          
            Industry
          
          
            Time Required
          
        Industry
              Tool Repair
          Time Required
              30 minutes
          
            Segment
          
          
            Substrate
          
                   
           
                       
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     Fabricated Metal Product
                     
                     
                    
          
        
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     
                     Aluminum
                     Nickel Alloys
                     Stainless Steel
                     
                     
                      
          
        
            Soil
          
        
                                                                                                                                                                                                                                                                                                                                Cutting Fluids                    Oil,                     Shop Dirt                                                    
          
        
            Description of Part(s)
          
        Description of Part
              Assortment of machine brackets/braces, connectors
          
            Cleaner Used
          
        10% by volume ARMAKLEEN™ M-Aero
            Machine Used
          
  Machine Used
              Spray Under Immersion (SK Model 81.8, Graymills T12, Graymills T24 w/ SUI)
            Post Cleaning
          
        Post Cleaning
              Fresh water rinse and air pressure drying
            Recommendation to Customer
          
        Recommendation
              The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ M-Aero at 160°F in a Spray-Under Immersion Washer for a minimum of 15-30 minutes
 
        
    