Before
After

Cleaning Trial Summary

 

The customer was looking to improve their cleaning performance, eliminate hazardous chemicals/waste and reduce VOCs.

Cleaning Trial Type
Temperature
Paint
150°F
Industry
Time Required
Coating Manufacturer
6 hours
Segment
Substrate
Fabricated Metal Product
Steel
Soil
Cured liquid epoxy paint
Description of Part(s)
Steel bar
Cleaner Used
Machine Used

Agitated Immersion Spray Washer (SK Model 81.8, Graymills T24)

Post Cleaning

Fresh water rinse followed by air pressure drying

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 100% by volume solution of ArmaKleen™ Paint and Ink Remover at 150°F in an Agitating Immersion Washer for a minimum of 6 hours.