Before
After

Cleaning Trial Summary

 

Improve cleaning performance

Cleaning Trial Type
Temperature
Aqueous
160°F, 150°F
Industry
Time Required
Paint Manufacturing
1 hour
Segment
Substrate
Chemical Distributor
Steel
Soil
Oil
Description of Part(s)
Shafts
Cleaner Used

5% by volume solution ARMAKLEEN™ 4 in 1 NF Cleaner

Machine Used

Spray Washer (JRI FL 250, JRI FL 500, JRI TL 500), Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)

Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in a Spray Washer or at 150°F in a Spray-Under Immersion Washer (Model 81.8 with attached spray pump) for a minimum of 15 minutes to 1 hour