Before
After

Cleaning Trial Summary

 

Improve cleaning performance, automate cleaning process, reduce rework and reject rate

Cleaning Trial Type
Temperature
Mold Cleaning
150°F
Industry
Time Required
Refractory Products Manufacturing
1 hour
Segment
Substrate
Non-metal Manufacturing
Plastic
Soil
Cement residue, Concrete residue
Description of Part(s)
Molds
Cleaner Used
Machine Used

Agitating Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8)

Post Cleaning

Several areas lightly brushed with a nylon bristle brush during the fresh water rinse and air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ Rust Remover at 150°F in an Agitating Immersion Washer (Model 81.8) for a minimum of 1 hour