Before
After

Cleaning Trial Summary

 

Improve cleaning performance and automate cleaning process

Cleaning Trial Type
Temperature
Aqueous
160°F
Industry
Time Required
Metalworking
1 hour
Segment
Substrate
Fabricated Metal Product
K500, Monel QQN-281, Stainless Steel
Soil
Cutting Fluids, Grease, Molykote P37
Description of Part(s)
Process machine components
Cleaner Used

10% by volume ARMAKLEEN™ M-HP-2

Machine Used
  • Ultrasonic Washer (SK Blackstone 6315)
  • Spray Washer (JRI FL 250, JRI FL 500, JRI TL 3)
Post Cleaning

Some parts were rinsed with fresh water and air pressure dried, while other parts were only air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ M-HP-2 at 160°F in an Ultrasonic Washer for a minimum of 1 hour or a 10% by volume solution of ArmaKleen™ M-HP-2 at 160°F in a Spray Washer for a minimum of 1 hour, both with a fresh water rinse