Before
After

Cleaning Trial Summary

 

Improve cleaning performance, clean mixed metals together

Cleaning Trial Type
Temperature
Aqueous
160°F
Industry
Time Required
Steel and Mining
30 minutes to 1 hour
Segment
Substrate
Civil/Heavy Construction
Glass, Plastic, Steel
Soil
Grime, Shop Dirt
Description of Part(s)
Lens cover, plastic cover, and clip
Cleaner Used

5% by volume ArmaKleen™ Bio 24

Machine Used

Spray Washer (JRI FL 250, JRI FL 500, JRI TL 3)

Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 160°F in a Spray-Under Immersion Washer for a minimum of 1 hour