Before
After

Cleaning Trial Summary

 

Improve cleaning performance and automate cleaning process

Cleaning Trial Type
Temperature
Epoxy paint
150°F
Industry
Time Required
Coatings Manufacturing
2 hours
Segment
Substrate
Chemical Manufacturing
Stainless Steel
Soil
Adhesive, Epoxy e-coat paint, Glue, Silicone
Description of Part(s)
Mesh filters
Cleaner Used
Machine Used

Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)

Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 100% by volume solution of ArmaKleen™ Paint and Ink Remover at 160°F in a Spray-Under Immersion Washer for a minimum of 2 hours