Before
After

Cleaning Trial Summary

 

Improve cleaning performance and automate cleaning process

Cleaning Trial Type
Temperature
Paint
160°F
Industry
Time Required
Concrete Building Systems Development
15-30 minutes
Segment
Substrate
Non-metal Manufacturing
Aluminum
Soil
Cured acrylic paint, PTFE Dry Coating Lubricant, Rust/Oxides, Shop Dirt
Description of Part(s)
Cylinders/dies
Cleaner Used
Machine Used

Ultrasonic Washer (SK Blackstone 6315)

Post Cleaning

Some parts were rinsed with fresh water and air pressure dried, and some were only air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 100% by volume solution of ArmaKleen™ Paint and Ink Remover at 160°F in an Ultrasonic Washer for a minimum of 15-30 minutes