Before
After

Cleaning Trial Summary

 

Improve cleaning performance, automate cleaning process, reduce rework and reject rate

Cleaning Trial Type
Temperature
Aqueous
150°F
Industry
Time Required
Watch Parts Manufacturing
15 minutes-2 hours
Segment
Substrate
Non-metal Manufacturing
Stainless Steel, Steel
Soil
Grease, Grime, Oil
Description of Part(s)
Assortment of cylinders, disks, rings
Cleaner Used

5% by volume ArmaKleen™ Bio 24

Machine Used

Spray Under Immersion (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)

Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 150°F in a Spray-Under Immersion Washer for a minimum of 15 minutes to 2 hours