Before
After

Cleaning Trial Summary

 

Improve cleaning performance, automate cleaning process, reduce rework and reject rate, reduce cleaning costs

Cleaning Trial Type
Temperature
Aqueous
160°F, 160°F, 150°F
Industry
Time Required
Pulverizer Manufacturing
2 hours
Segment
Substrate
Machine Manufacturing
Steel
Soil
Oil
Description of Part(s)
Assortment of male and female clips
Cleaner Used

5% by volume ArmaKleen™ Bio 24

Machine Used
  • Spray Washer (JRI FL 250, JRI FL 500, JRI TL 3)
  • Ultrasonic Washer (SK Blackstone 6315)
  • Spray Under Immersion washer (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)
Post Cleaning

Fresh water rinse and air pressure dried, followed by further drying in an incubator at 220°F

 

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 150°F in a Spray-Under Immersion Washer for a minimum of 30 minutes to 2 hours or a 5% by volume solution of ArmaKleen™ Bio 24 at 160°F in a Spray Washer or an Ultrasonic Washer for a minimum of 30 minutes to 2 hours