Before
After

Cleaning Trial Summary

 

Improve cleaning performance, automate cleaning process, eliminate hazardous chemicals/waste, reduce VOCs

Cleaning Trial Type
Temperature
Paint
150°F
Industry
Time Required
Oil Refining
8 hours
Segment
Substrate
Chemical Manufacturing
Stainless Steel, Steel
Soil
Baked on Carbon, Epoxy powder coat paint, Grease, Grime, liquid alkyd paint, Liquid epoxy paint, liquid polyester paint, Liquid urethane paint, Oil, polyester powder coat paint, Rust/Oxides, Shop Dirt, Silicone
Description of Part(s)
Pistons housing unit
Cleaner Used

5% by volume ArmaKleen™ Bio 24

Machine Used

Agitating Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8)

Post Cleaning

Fresh water rinse and air pressure dried, followed by drying in an incubator at 220°F

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 150°F in an Agitating Immersion Washer or at 150°F for a minimum of 8 hours