Before
After

Cleaning Trial Summary

 

Automate cleaning process and have cleaned/dried parts be rust-free

Cleaning Trial Type
Temperature
Aqueous
160°F
Industry
Time Required
Metal-working
15 minutes
Segment
Substrate
Fabricated Metal Product
Aluminum, Steel
Soil
Vibratory residue
Description of Part(s)
Ductile iron machined cast dies
Cleaner Used

5% by volume ArmaKleen™ Bio 24

Machine Used

Spray Under Immersion (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)

Post Cleaning

Fresh water rinse and air pressure dried, followed by parts being placed in an incubator at 220°F

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 160°F in a Spray-Under Immersion Washer for a minimum of 15 minutes