Before
After

Cleaning Trial Summary

Auto Maintenance :: TSR #19-A-067

 

Improve cleaning performance and automate cleaning process

Cleaning Trial Type
Temperature
Aqueous
160°F
Industry
Time Required
Automotive Maintenance
1 hour
Segment
Substrate
Auto Maintenance
Aluminum, Iron
Soil
Grease, Grime, Oil
Description of Part(s)
Turbocharger housings
Cleaner Used
Machine Used
  • Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)
  • Ultrasonic Washer (SK Blackstone 6315)
Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 10% by volume solution ArmaKleen™ M-100BCR at 160°F in a Spray Under Immersion Washer or an Ultrasonic Washer for a minimum of 1 hour