Before
After

Cleaning Trial Summary

 

Improve cleaning performance and reduce cleaning costs

Cleaning Trial Type
Temperature
Aqueous
160°F
Industry
Time Required
Metal Manufacturing
15-60 minutes
Segment
Substrate
Fabricated Metal Product
Copper/brass
Soil
Drawing Lube, Oil
Description of Part(s)
Small caps
Cleaner Used

5% by volume ArmaKleen™ Bio 24

Machine Used

Ultrasonic Washer (SK Blackstone 6315)

Post Cleaning

Fresh water rinse followed by drying in an incubator at 108°C

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume of ArmaKleen™ BIO-24 at 160°F in an Ultrasonic Washer for a minimum of 15 to 60 minutes