Before
After

Cleaning Trial Summary

 

Improve cleaning performance, automate cleaning process, redce rework and reject rate, reduce cleaning costs

Cleaning Trial Type
Temperature
Aqueous
160°F
Industry
Time Required
Compression Tehnology
15-30 minutes
Segment
Substrate
Machine Manufacturing
Stainless Steel, Steel
Soil
Cutting Fluids, Grease, Oil, Shop Dirt
Description of Part(s)
Disks
Cleaner Used

55 by volume ArmaKleen™ Bio 24

Machine Used

Ultrasonic Washer (SK Blackstone 6315)

Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 160°F in an Ultrasonic Washer for a minimum of 60+ minutes