Before Picture
Before
After Picture
After

Cleaning Trial Summary

 

The customer was looking to improve their cleaning performance, reduce rework and reject rate, reduce their cleaning costs and eliminate hazardous chemicals and waste.

Cleaning Trial Type
Temperature
Aqueous
160⁰F
Industry
Time Required
OEM Parts Manufacturing
15 to 30 minutes
Segment
Substrate
Fabricated Metal Product
Aluminum
Soil
Cutting Fluids, Oil, Shop Dirt
Description of Part(s)
Aluminum brackets
Cleaner Used
Machine Used

Spray Under Immersion Washer (Graymills T12, Graymills T24, SK 81.8 w/SUI)

Post Cleaning

Fresh water rinse followed by air pressure drying.

Recommendation to Customer

The ArmaKleen Technical Center recommended using 5% by volume ArmaKleen™ 4 in 1 Cleaner at 160⁰F in a Spray Under Immersion Washer for a minimum of 15 to 30 minutes.