Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #17-P-116

 

Customer Objective

The customer was looking to improve their cleaning performance, reduce rework and reject rate, reduce their cleaning costs and eliminate hazardous chemicals/waste.

Cleaning Trial Type
Temperature
Adhesive
Temperature
160°F
Industry
Time Required
Industry
Brush Manufacturer
Time Required
30 minutes to 2 hours
Segment
Substrate
Machine Manufacturing
Nylon Stainless Steel
Soil
Adhesive, Glue
Description of Part(s)
Description of Part
an assortment of nylon bristle brushes on stainless steel stems
Cleaner Used
Machine Used
Machine Used

Ultrasonic Washer (SK Blackstone model 6315)

Post Cleaning
Post Cleaning

Fresh rinse followed by air pressure drying 

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 100% by volume solution of ArmaKleen™ Paint and Ink Remover at 160°F in an Ultrasonic Washer for a minimum of 30 minutes to 2 hours.