Before
After

Cleaning Trial Summary

 

The customer was looking to automate their cleaning process

Cleaning Trial Type
Temperature
Aqueous
160°F
Industry
Time Required
Hydraulic Cylinder Manufacturer
30 minutes
Segment
Substrate
Machine Manufacturing
Stainless Steel
Soil
Cutting Fluids, Grime, Oil
Description of Part(s)
a stainless steel connector/die
Cleaner Used
Machine Used

Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000

Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in a TL-Spray Washer for a minimum of 30 minutes.