Before
After

Cleaning Trial Summary

Building Material :: TSR #17-A-195

 

Improve cleaning performance, automate cleaning process, reduce rework/reject rate

Cleaning Trial Type
Temperature
Rust
160°F
Industry
Time Required
Glass manufacturing
2 hours
Segment
Substrate
Building Material
Stainless Steel
Soil
Rust/Oxides
Description of Part(s)
Glass vial molds
Cleaner Used
Machine Used

Ultrasonic (SK Blackstone 6315)

Post Cleaning

Fesh water rinse and air pressure drying

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ Rust Remover at 160°F in an Ultrasonic Washer for a minimum of 30 minutes to 2 hours