Before
After

Cleaning Trial Summary

 

Improve cleaning performance and automate cleaning process

Cleaning Trial Type
Temperature
Aqueous
150°F, 160°F
Industry
Time Required
Membrane Separators Manufacturing
2 hours
Segment
Substrate
Chemical Manufacturing
Steel
Soil
Anti-seize
Description of Part(s)
Bolts
Cleaner Used
Machine Used
  • Spray Under Immersion (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)
  • Ultrasonic (SK Blackstone 6315)
Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ 4 in 1 Cleaner at 160°F in an Ultrasonic Washer for a minimum of 1-2 hours