Before
After

Cleaning Trial Summary

 

Improve cleaning performance, automate cleaning process, reduce cleaning costs

Cleaning Trial Type
Temperature
Aqueous
150°F
Industry
Time Required
Welding Products
30 minutes to 1 hour
Segment
Substrate
Machine Manufacturing
Copper, Stainless Steel
Soil
Cutting Fluids, Oil, Shop Dirt
Description of Part(s)
Connectors
Cleaner Used

5% by volume ArmaKleen™ Bio 24

Machine Used

Spray Under Immersion (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)

Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 150°F in a Spray-Under Immersion Washer for a minimum of 30 minutes to 1 hour