Before
After

Cleaning Trial Summary

 

Improve cleaning performance, automate cleaning process, reduce rework and reject rate

Cleaning Trial Type
Temperature
Aqueous
150°F, 160°F
Industry
Time Required
Automotive Parts Manufacturing
30 minutes-2 hours
Segment
Substrate
Transportation Equipment Manufacturing
Steel
Soil
Baked on Carbon, Oil
Description of Part(s)
Assortment of pins
Cleaner Used
Machine Used
  • Agitating Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8)
  • Ultrasonic Washer (SK Blackstone 6315)
Post Cleaning

Half of the parts were rinsed with fresh water and air pressure dried, while the other half were not rinsed and only air pressured dried; all parts were placed in an incubator at 220°F for further drying

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ M-100 BCR at 150°F in an Agitating Immersion Washer for a minimum of 30 minutes to 2 hours