Before
After

Cleaning Trial Summary

 

Improve cleaning performance

Cleaning Trial Type
Temperature
Aqueous
120°F, 150°F
Industry
Time Required
Automotive
15 minutes
Segment
Substrate
Transportation Equipment Manufacturing
Steel
Soil
Oil
Description of Part(s)
Manufactured bolts
Cleaner Used

5% by volume ArmaKleen™ Bio 24

Machine Used

Agitating Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8)

Post Cleaning

Fresh water rinse and air pressure dried, followed by parts being placed in an incubator at 212°F

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio24 at 150°F in an Agitating Immersion Washer (model 81.8) for a minimum of 15 minutes