Before
After

Cleaning Trial Summary

 

Improve cleaning performance and automate cleaning process

Cleaning Trial Type
Temperature
Polymer
160°F
Industry
Time Required
Engineered Products Manufacturing
8-14 hours
Segment
Substrate
Non-metal Manufacturing
Iron, Steel
Soil
Thermoplastic Elastomer, Thermoplastic Valcanigales
Description of Part(s)
Extrusion components
Cleaner Used
Machine Used

Ultrasonic Washer (SK Blackstone 6315)

Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 100% by volume of ArmaKleen™ Paint & Ink Remover at 160°F in an Ultrasonic Washer for a minimum of 8 to 14 hours