Before
After

Cleaning Trial Summary

 

Improve cleaning performance, automate cleaning process, reduce rework and reject rate, clean mixed metals together, reduce cleaning costs, utilize one cleaner for all types of metals

Cleaning Trial Type
Temperature
Aqueous
160°F
Industry
Time Required
Machine Manufacturing
15-30 minutes
Segment
Substrate
Fabricated Metal Product
Aluminum, Copper/brass, Iron, Stainless Steel, Steel
Soil
Cutting Fluids, Oil
Description of Part(s)
Assortment of screws, nuts, bolts
Cleaner Used

5% by volume ArmaKleen™ Bio 24

Machine Used
  • Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)
  • Ultrasonic Washer (SK Blackstone 6315)
Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume of ArmaKleen™ BIO-24 at 160°F in a Spray Under Immersion Washer for a minimum of 15 to 30 minutes or a 5% by volume solution of ArmaKleen™ BIO-24 at 160°F in an Ultrasonic Washer for a minimum of 15 to 30 minutes